UV proof tester - Qinsun
Professzionális vizsgálóműszerek gyártója
Nemzeti konzultációs hotline:+86 021-64208466
Termékek

UV proof tester

SPF Record Checker Product details:It includes the closest spectral characteristics of the sun's lig

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Tartalom

Részletek

It includes the closest spectral characteristics of the sun's light source, high stability of the UV-visible spectrophotometer, fully functional control and data analysis software. It replaces the human body (In-VIVO) to measure the SPF value and various other important indexes of sun protection products and cosmetics, making measurement cost more economical, faster and more convenient.

Standard

COLIPA in-vitro method for UVA-PF/SPF ratio

Critical Wavelength (EU Labeling)

FDA Critical Wavelength (US Labeling)

Monograph FDA 21 CFR

AATCC 183

AS/NZS 4399

Australian TNUV Standards

UVA/UVB

UVA Protective Factor Calculations

ISO:2442

Jellemzők

1. Cover the spectral region of UVA and UVB, spectral range: 290-400nm, wavelength repeatability: 0.25nm, the system data cumulative record storage interval 1.2.5 nm optional, monochrome resolution: 1.66nm, wavelength accuracy of ± 0.2% ;

2. Data acquisition and analysis software: It has the function of calculating and analyzing print data, the form of double output forms and graphics, built-in Boots Star rating calculation mode, the cumulative test up to 36 units, automatic display MPF and absorbance values, with light stability, Automatic calculation of UVA, UVB, UPF value, critical wavelength, UVA in vitro testing, networking and convenient online help mode;

3. 125W xenon arc light source to provide stable UV and near ultraviolet radiation, high-performance integral ball to ensure good test accuracy;

4. One-year NIST data traceability;

5. 99.997% linearity;

6. Software control Sampling platform: provide automatic scanning test and timing measurement, the software set the test mode, 12 sampling points, automatic continuous test, the test is completed automatically stop to generate the saved data; to meet the standard test and light resistance for a long time test;

7. Configure the NIST verification calibration kit so that the user can calibrate and maintain the instrument

Paraméter

Wavelength range

290-400nm

Wavelength accuracy

0.2%

Wavelength reproducibility

0.25nm

Spectral FWHM bandwidth

1.66nm

Absorbance

0-3.2A

SPF measurement range

1-50+

Scan speed

25s

Minimum wavelength interval

1nm,2nm,5nm

Lamp

Continuous stable xenon lamp

Detector

Photomultiplier tube

Sample positioning

Automated X-Y translation stage

Power supply options

110VAC,60HZ,220VAC,50HZ



UV PROOF.jpg


Felelősségi nyilatkozat: A fenti tartalom kizárólag az iparági belső személyek közötti hivatkozásra és kommunikációra szolgál, és nem garantálja pontosságát vagy teljességét. A vonatkozó törvények és előírások, valamint a weboldal előírásai szerint a kapcsolódó cikkeket vásárló egységeknek vagy egyéneknek érvényes képesítést és képesítési feltételeket kell megszerezniük.


Online üzenet

Kapcsolat adatai

Vállalati telefon

+86-21-6420 0566

munkaidő

Hétfőtől péntekig

Mobiltelefon:

13816217984

E-mail:

info@qinsun-lab.com

QR kód