Precision HV Flame Chamber for Flammability Compliance Testing.
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
ANSI/UL 94: Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances
GJB 360B-2009: Test Methods for Electronic and Electrical Components (Military Standard)
GB/T 5169.16-2008: Fire Hazard Testing – Part 16: Correlation of Thermal and Mechanical Surface Flammability
IEC 60950-1: Safety of Information Technology Equipment
ISO 13943: Fire Safety – Vocabulary (Referenced for Flammability Testing)
Dual-Mode Testing: Supports horizontal/vertical combustion analysis (0°, 20°, 45° angles).
Full Automation: PLC + touchscreen control for ignition, timing, data logging, and burner retraction.
Precision Control: Adjustable flame height (20–130 mm), temperature (100–1000°C), and gas flow (0–1000 ml/min).
Safety Compliance: Auto-gas shutoff, silent exhaust system, and optional gas alarm reduce operational risks.
Data-Driven: Auto-calculates linear combustion rate (V) and stores results for regulatory compliance.
Flexible Sample Handling: Adjustable clamps accommodate diverse material sizes and thicknesses.
Touchscreen Interface: Programmable controller with one-touch operation for ignition, timing, and data storage.
Automatic Burner System: Retracts post-test; optional gas shutoff prevents residual flames.
Flame Calibration: Optional thermocouple (K-type) and copper block ensure precise temperature control (100–700°C in ≤44s).
Multi-Angle Testing: Adjustable sample holder for horizontal (0°), 20°, or 45° vertical combustion.
High-Capacity Chamber: >0.5 m³ stainless steel box (non-calibrated options: 0.75 m³/1 m³) with black background (<20 Lux).
Exhaust System: Silent anti-backflow device removes combustion smoke post-test.
Paraméter | Specifikáció |
---|---|
Test Modes | Horizontal/Vertical (0°, 20°, 45°) |
Vezérlőrendszer | PLC + 7-inch Touchscreen |
Flame Height | 20–130 mm (Adjustable) |
Flame Temperature | 100–1000°C (Adjustable) |
Gas Flow | 0–1000 ml/min (Adjustable) |
Burner Specs | Inner Diameter: 9.5 ±0.3 mm; Length: 100 ±10 mm |
Timer Range/Accuracy | 0–999.9 s (±0.2 s for 10s/30s) |
Combustion Rate (V) | Auto-Calculated by PLC (Displayed/Saved) |
Sample Adjustment | Up/Down, Left/Right, Front/Back (Large Stroke) |
Chamber Volume | >0.5 m³ (900 × 590 × 1050 mm) |
Tápegység | AC 220V ±10%, 50Hz, 150W |
Dimensions (W×D×H) | 1160 × 600 × 1310 mm (Incl. Feet) |
Net Weight | 100 kg |
Gas Source | Liquefied Petroleum Gas (Methane for Arbitration) |
Felelősségi nyilatkozat: A fenti tartalom kizárólag az iparági belső személyek közötti hivatkozásra és kommunikációra szolgál, és nem garantálja pontosságát vagy teljességét. A vonatkozó törvények és előírások, valamint a weboldal előírásai szerint a kapcsolódó cikkeket vásárló egységeknek vagy egyéneknek érvényes képesítést és képesítési feltételeket kell megszerezniük.