Prepares safety helmets with UV irradiation before testing per standards.
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Termék bevezetése:
Helmet ultraviolet pretreatment box is used for helmet ultraviolet irradiation pretreatment, according to the new national standard GB/T 2812-2006 "Helmet test method", GB/T 2811-2019 "helmet" development, widely used in special labor protection equipment supervision and inspection station, building science research institute, construction engineering inspection station.
Product Advantages:
Performs Standardized Pretreatment: Provides a controlled environment for UV irradiation according to relevant safety helmet testing standards.
Simulates Natural Aging: Replicates the aging effects of sunlight exposure on helmet materials, preparing them for realistic performance assessment.
Essential for Durability Testing: Allows laboratories to evaluate the long-term durability and safety of helmets after simulated UV degradation.
Standard Compliant: Developed in accordance with national standards GB/T 2812 and GB/T 2811.
Efficient: Capable of pretreating multiple helmets simultaneously.
Widely Used: Adopted by key testing and research institutions in the field of labor protection equipment.
Controllable Exposure Time: Features a timer to control the duration of UV irradiation.
Product Features:
UV irradiation chamber or enclosure designed to contain safety helmets during exposure.
Specific ultraviolet radiation source (450W high pressure short pulse xenon lamp) designed to emit UV radiation that simulates the spectrum of sunlight.
Cooling method (air-cooled) to manage the heat generated by the UV lamp, maintaining a controlled temperature environment within the chamber (although specific temperature control parameters are not listed).
Internal rack or fixture system capable of holding multiple helmets (from 1 to 14) in position for uniform UV exposure.
Timer with a wide range (0-999 hours) to control the duration of the UV irradiation pretreatment.
Robust construction suitable for laboratory use and the specific environmental conditions required for UV aging.
Safety features (implied) to prevent operators from being exposed to harmful UV radiation during operation.
Main parameters:
1, ultraviolet radiation source: 450W high pressure short pulse xenon lamp
2, Cooling method: air-cooled
3, timing range: 0-999 hours
4, the number of pretreatment helmets: 1--14
5, Working power supply: AC220V 50Hz 800W
Felelősségi nyilatkozat: A fenti tartalom kizárólag az iparági belső személyek közötti hivatkozásra és kommunikációra szolgál, és nem garantálja pontosságát vagy teljességét. A vonatkozó törvények és előírások, valamint a weboldal előírásai szerint a kapcsolódó cikkeket vásárló egységeknek vagy egyéneknek érvényes képesítést és képesítési feltételeket kell megszerezniük.