I. Product Overview
The Drapery Flammability Tester is a specialized instrument designed to evaluate the flame resistance of textiles and drapery materials in compliance with international fire safety standards. It simulates real-world fire scenarios to quantify ignition resistance, flame spread, and self-extinguishing properties.
- Type: Vertical/horizontal flame propagation tester
- Test Standards: NFPA 701, ASTM D6413, ISO 6941
- Flame Source: Propane gas burner (12mm nozzle)
- Sample Size: 610×1220mm (vertical) / 610×2440mm (horizontal)
- Key Metrics:
- Flame Spread Time (seconds)
- Char Length (mm)
- Afterflame/Afterglow Duration
II. Technical Specifications
Paraméter |
Specifications |
Burner Type |
Gas-fired, 12mm ceramic nozzle (propane) |
Flame Height |
125±5mm (adjustable via gas flow) |
Test Duration |
10–120 seconds (programmable) |
Flame Propagation Sensor |
High-speed thermal camera (120Hz) |
Tápegység |
220V/50Hz, 2.5kW |
Méretek |
1500×800×1800mm (L×W×H) |
III. Key Features
- Dual Test Modes:
- Vertical Test: Evaluates upward flame spread
- Horizontal Test: Measures lateral ignition resistance
- Advanced Detection:
- Real-time thermal imaging (°C gradient mapping)
- AI-based flame front tracking
- Automatic char length measurement (±1mm accuracy)
- Automation:
- Motorized burner positioning
- Programmable gas flow control
- Self-cleaning exhaust system
IV. Compliance Standards
- NFPA 701 (Standard Methods for Fire Tests of Draperies)
- ASTM D6413 (Vertical Ignition Resistance)
- ISO 6941 (Textile flame propagation)
- BS 5852 (UK flammability standard)
V. Applications
- Textile Manufacturing: Certifying fabrics for public buildings
- Interior Design: Evaluating drapery fire resistance
- Fire Safety Departments: Compliance testing for hotels/hospitals
- R&D: Developing flame-retardant coatings
Standard Operation Workflow:
- Sample Preparation: Cut to size, clamp vertically/horizontally
- Calibration: Reference fabric validation
- Testing: Ignite burner at specified height/duration
- Analysis: Generate flame spread velocity curves
- Cleaning: Automated soot extraction system
Safety Precautions:
- Fire-rated enclosure required (class A60)
- PPE mandatory (heat-resistant gloves, goggles)
- Fire extinguisher (Class B) must be on standby

Felelősségi nyilatkozat: A fenti tartalom kizárólag az iparági belső személyek közötti hivatkozásra és kommunikációra szolgál, és nem garantálja pontosságát vagy teljességét. A vonatkozó törvények és előírások, valamint a weboldal előírásai szerint a kapcsolódó cikkeket vásárló egységeknek vagy egyéneknek érvényes képesítést és képesítési feltételeket kell megszerezniük.